Model | Certification |
---|---|
Eagle (all) | Russian certification - The Russian declaration of conformity GOST TR, EAC and Ex |
Eagle (all) | Ukranian certification - Ukrainian declaration of conformity UkrSEPRO, Ex |
Eagle (all) | Ordinary locations and Hazardous Locations Class II Div. 1 & 2 Groups E, F, & G; T5 (US and CAN) Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use - Part 1: General Requirements [UL 61010-1:2012 Ed.3] Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use Part 1: General Requirements [CSA C22.2#61010-1-12:2012 Ed.3] FM 3600 Issue:2011/12/01 Electric Equipment for Use in Hazardous (Classified) Locations - General Requirements FM 3616 Issued: 2011/12/01 Dust - Ignitionproof Electrical Equipment - General Requirements Enclosures For Use In Class II Groups E, F, And G Hazardous Locations (R2014) [CSA C22.2#25:1966 +G1] |
Andco 7000 series | Ordinary locations and Hazardous Locations Class II Div. 1 & 2 Groups E, F, & G; T4A Type 4 (US and CAN) Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 1: General Requirements; UL 61010-1; Issued: 2012/05/11 Ed: 3 Rev: 2015/07/15 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use – Part 1: General Requirements - General Instruction; CSA C22.2 No. 61010-1; Issued: 2015/07/15 FM 3600 Issue:2011/12/01 Electric Equipment for Use in Hazardous (Classified) Locations -General Requirements FM 3616 Issued: 2011/12/01 Dust - Ignitionproof Electrical Equipment – General Requirements CSA C22.2#25 Issued: 1966/09/01 (R2014) Enclosures for Use in Class II Groups E, F, and G Hazardous Locations; Gen. Inst. No. 1: 1966 |
Surepowr 150 | CLASS – 3211 06 – INDUSTRIAL CONTROL EQUIPMENT – Motor Controllers - Miscellaneous CLASS – 3211 86 – INDUSTRIAL CONTROL EQUIPMENT – Motor Controllers - Miscellaneous – Certified to U.S. and Canadian Standards CAN/CSA-C22.2 No. 0-10 General requirements — Canadian Electrical Code, Part II CSA C22.2 No. 14-13 Industrial Control Equipment CSA Std. C22.2 No. 94-M91 Special Purpose Enclosures UL 50. Enclosures for Electrical Equipment UL 508 Industrial Control Equipment |
Surepowr 150 | -Class I, Division 1, Groups C and D, Class II, Division 1, Groups E, F and G (US Only); T6 -CLASS 3218 85 – INDUSTRIAL CONTROL EQUIPMENT – MotorControllers – Miscellaneous – For Hazardous Locations – Certified to U.S. Standards UL 50, 12th Ed - Enclosures for Electrical Equipment UL 508, 17th Ed - Industrial Control Equipment UL 1203: 4th Edition - Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations -Letter of Attestation received for Hydrostatic Overpressure Test & Explosion Flame Propagation Test to CSA-C22.2 No 30M1986 - Pending CAN certifications |
Surepowr 150 | - ATEX - Ex II GD - IECEx - II 2 GD - Certified to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment intended for use in potentially explosive atmospheres given in Annex II to the Directive. - Rotary Actuators - Equipment intended for use in Potentially Explosive Atmospheres Directive 2014/34/EU |
Electripowr MARs | -CLASS -C322102 -VALVES - General purpose Actuators -CLASS -C322182 - VALVES - Actuators -Certified to US and Canadian Standards CAN/CSA-C22.2 No. 0-10 General requirements — Canadian Electrical Code, Part II CSA C22.2 No. 14-13 Industrial Control Equipment CSA Std. C22.2 No. 94-M91 Special Purpose Enclosures UL 50, 12th Ed. Enclosures for Electrical Equipment UL 508 17th EditionIndustrial Control Equipment |
Electripowr MARs | -Class I, Division 1, Groups C and D, Class II, Division 1, Groups E, F and G (US and CAN); T6 -CLASS - C322802 - VALVES-Actuators - For Hazardous Locations -CLASS - C322882 - VALVES-Actuators - For Hazardous Locations - Certified to U.S. and Canadian Standards CAN/CSA-C22.2 No. 0-10-General requirements —Canadian Electrical Code, Part II CSA Std. C22.2 No. 25-1966-Enclosures for Use in Class II, Groups E, F and G Hazardous Locations CSA Std. C22.2 No. 30-M1986-Explosion-Proof Enclosures for Use in Class I Hazardous Locations CSA Std. C22.2 No. 77-95-Motors with Inherent Overheating Protection CSA Std. C22.2 No. 94-M91-Special Purpose Enclosures CSA Std. C22.2 No. 139-10-Electrically Operated Valves UL Std. No. 50: 12th Edition-Enclosures for Electrical Equipment UL Std. No. 429: 6th Edition-Electrically Operated Valves UL Std. No. 1203: 4th Edition-Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations |
Surepowr 24/25 | CLASS -C322102 -VALVES - General purpose Actuators CLASS -C322182 - VALVES - Actuators -Certified to US Standards CAN/CSA-C22.2 No. 0-10 General requirements — Canadian Electrical Code, Part II CSA C22.2 No. 14-13 Industrial Control Equipment CSA Std. C22.2 No. 94-M91 Special Purpose Enclosures UL 50, 12th Ed. Enclosures for Electrical Equipment UL 508 17th EditionIndustrial Control Equipment |
Surepowr 24/25 | Class I, Division 1, Groups C and D, Class II, Division 1, Groups E, F and G; T6 (US and CAN) CLASS - C322802 - VALVES-Actuators - For Hazardous Locations CLASS - C322882 - VALVES-Actuators - For Hazardous Locations-Certified to U.S. Standards CAN/CSA-C22.2 No. 0-10-General requirements —Canadian Electrical Code, Part II CSA Std. C22.2 No. 25-1966-Enclosures for Use in Class II, Groups E, F and G Hazardous Locations CSA Std. C22.2 No. 30-M1986-Explosion-Proof Enclosures forUse in Class I Hazardous Locations CSA Std. C22.2 No. 77-95-Motors with Inherent Overheating Protection CSA Std. C22.2 No. 94-M91-Special Purpose Enclosures CSA Std. C22.2 No. 139-10-Electrically Operated Valves UL Std. No. 50: 12th Edition-Enclosures for Electrical Equipment UL Std. No. 429: 6th Edition-Electrically Operated Valves UL Std. No. 1203: 4th Edition-Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations |
Surepowr 100 | CLASS -C322102 -VALVES-General purpose Actuators CLASS -C322182 - VALVES-Actuators -Certified to US Standards CAN/CSA-C22.2 No. 0-10 General requirements — Canadian Electrical Code, Part II CSA C22.2 No. 14-13 Industrial Control Equipment CSA Std. C22.2 No. 94-M91 Special Purpose Enclosures UL 50, 12th Ed. Enclosures for Electrical Equipment UL 508 17th Edition Industrial Control Equipment |
Surepowr 100 | Class I, Division 1, Groups C and D, Class II, Division 1, Groups E, F and G; T6 (US and CAN) CLASS - C322802 - VALVES-Actuators - For Hazardous Locations CLASS - C322882 - VALVES-Actuators - For Hazardous Locations - Certified to U.S. Standards CAN/CSA-C22.2 No. 0-10-General requirements —Canadian Electrical Code, Part II CSA Std. C22.2 No. 25-1966-Enclosures for Use in Class II, Groups E, F and G Hazardous Locations CSA Std. C22.2 No. 30-M1986-Explosion-Proof Enclosures for Use in Class I Hazardous Locations CSA Std. C22.2 No. 77-95-Motors with Inherent Overheating Protection CSA Std. C22.2 No. 94-M91-Special Purpose Enclosures CSA Std. C22.2 No. 139-10-Electrically Operated Valves UL Std. No. 50: 12th Edition-Enclosures for Electrical Equipment UL Std. No. 429: 6th Edition-Electrically Operated Valves UL Std. No. 1203: 4th Edition-Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations |
Surepowr 100 | -ATEX, -Ex II GD -IECEx -II 2 GD -Certified to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment intended for use in potentially explosive atmospheres given in Annex II to the Directive. -Rotary Actuators - Equipment intended for use in Potentially Explosive Atmospheres Directive 2014/34/EU |
Surepowr 65 | Class I, Div 1, Group C and D, Class II, Group E, F and G, Class III; T6 (US and CAN) Ex d IIB Gb, Ex tb IIIC T85°C Db IP 66/67 Class I, Zone 1, AEx d IIB T6 Gb Zone 21, AEx tb, IIIC T85°C Db CLASS - C322102 - VALVES General purpose Actuators CLASS - C322182 - VALVES Actuators - Certified to US Standards CLASS - C322802 - VALVES Actuators - For Hazardous Locations CLASS - C322882 - VALVES Actuators - For Hazardous Locations - Certified to U.S. and Canadian Standards C22.2 No. 0-10 General requirements — Canadian Electrical Code, Part II C22.2 No. 25-1966 (R2009) Enclosures for Use in Class II Groups E, F, and G Hazardous Locations C22.2 No. 30-M1986 (R2016) Explosion-proof Enclosures for Use in Class I Hazardous Locations C22.2 No. 94.1-07 Enclosures for Electrical Equipment, Non-Environmental Considerations C22.2 No. 94.2-07, 2nd Ed. Enclosures for electrical equipment, environmental considerations C22.2 No. 139-13(R2016) Electrically operated valves CAN/CSA-C22.2 No. 60079-0:2015 Explosive atmospheres — Part 0: Equipment — General requirements CAN/CSA-C22.2 No. 60079- 1:2016 Explosive atmospheres — Part 1: Equipment protection by flameproof enclosures “d” CAN/CSA-C22.2 No. 60079-31:2015 Explosive atmospheres — Part 31: Equipment dust ignition protection by enclosure "t" CAN/CSA-C22.2 No. 60529:16 Degrees of protection provided by enclosures (IP Code) (IEC60529:1989+A1:1999+A2:2013, MOD) UL 50, 12th Ed. Enclosures for Electrical Equipment, Non-Environmental Considerations UL 50E, 2nd Ed. Enclosures for electrical equipment, environmental considerations UL 429, 7th Ed. Electrically Operated Valves UL 1203, 5th Ed. Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations UL 60079-0, 6 th Ed. Explosive atmospheres – Part 0: Equipment – General requirements UL 60079-1, 7th Ed. Explosive Atmospheres – Part 1: Equipment Protection by Flameproof Enclosures “d” UL 60079-31, 2nd Ed. Explosive Atmospheres – Part 31: Equipment Dust Ignition Protection by Enclosure “t” ANSI/IEC 60529:2004 (R2011) Degrees of Protection Provided by Enclosures (IP Code) |
DCR models 10,50,90,100,160,250 & 800's - 12 VDC (Limited Models and Speeds) | GENERAL PURPOSE ACTUATOR Class I, Division 1, Groups C and D, Class II, Division 1, Groups E, F and G; T5 (US and CAN) CLASS - C322802 - VALVES-Actuators - For Hazardous Locations CLASS - C322882 - VALVES-Actuators - For Hazardous Locations-Certified to U.S. Standards CAN/CSA-C22.2 No. 0-10-General requirements —Canadian Electrical Code, Part II CSA Std. C22.2 No. 25-1966-Enclosures for Use in Class II, Groups E, F and G Hazardous Locations CSA Std. C22.2 No. 30-M1986-Explosion-Proof Enclosures for Use in Class I Hazardous Locations CSA Std. C22.2 No. 77-95-Motors with Inherent Overheating Protection CSA Std. C22.2 No. 94-M91-Special Purpose Enclosures CSA Std. C22.2 No. 139-10-Electrically Operated Valves UL Std. No. 50: 12th Edition-Enclosures for Electrical Equipment UL Std. No. 429: 6th Edition-Electrically Operated Valves UL Std. No. 429: 7th Edition-Electrically Operated Valves UL Std. No. 1203: 4th Edition-Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations |
Accessories: | |
Positran Models 4201/02 & V051 | CLASS -C322102 -VALVES - General purpose Actuators CLASS -C322182 - VALVES-Actuators - Certified to US Standards |
Positran Models 4201/02 & V051 | Class I, Division 1, Groups C and D, Class II, Division 1, Groups E, F and G CLASS - C322802 - VALVES-Actuators - For Hazardous Locations CLASS - C322882 - VALVES-Actuators - For Hazardous Locations - Certified to U.S. Standards |
SCC10-115/230V | CLASS -C322102 -VALVES-General purpose Actuators CLASS -C322182 - VALVES-Actuators -Certified to US Standards |
SCC10-115/230V | Class I, Division 1, Groups C and D, Class II, Division 1, Groups E, F and G CLASS - C322802 - VALVES-Actuators - For Hazardous Locations CLASS - C322882 - VALVES-Actuators - For Hazardous Locations - Certified to U.S. Standards |
ACT100-110/220 AC | Class I, Division 1, Groups C and D, Class II, Division 1, Groups E, F and G CLASS - C322802 - VALVES-Actuators - For Hazardous Locations CLASS - C322882 - VALVES-Actuators - For Hazardous Locations - Certified to U.S. Standards -for use with all single phase 120/220V, 50/60Hz actuators. -certified temperature range -40C to 95C (-40F to 203F) |
Limit Switch Module for the RCS SurePowr Series Actuators, model PCB-V2 | CLASS 3211 06 -INDUSTRIAL CONTROL EQUIPMENT - Motor Controllers - Miscellaneous CLASS 3211 86 -INDUSTRIAL CONTROL EQUIPMENT - Motor Controllers - Miscellaneous - Certified to U.S. Standards CSA C22.2 No 14-13-Industrial Control Equipment UL 508, Edition17-Industrial Control Equipment TIL No. D-23A-Interim Requirements for Spacings in Solid State Industrial Control Equipment |